C500-RM SYSMAC BUS Remote I/O Master Wired C500-RM001-PV1.
APF/PCF.Name: Compact Connectors.
Specifications: Inputs; 2 outputs; PNP.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery.
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit CJ1M-CPU11-ETN REFERENCE MANUAL.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices
CJ1M-CPU11-ETN
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price.
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications. Supply voltage: 100 to 120 or 200 to 240 VAC, 50/60 Hz
Output capacity: DC5V, 6 CJ1M-CPU11-ETN REFERENCE MANUAL. 5AC500-IA I/O Unit AC Input 32 pts C500-IA122(3G2A5-IA122).
AC100-120V 10mA.ASCII Unit
This program runs independently from the ladder-diagram program in the PLC.
Name: ASCII Module.
Model: C200H-ASC11.
Communications port>Port 1: RS-232C(peripheral device or termi-nal connection).
Communications port>Port 2: RS-232C(peripheral deviUnit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units CJ1M-CPU11-ETN REFERENCE MANUAL.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, N, R, S, T, ±80mV.
Conversion speed: 150 ms/4 inputs.
Externa connection: Removable erminal block OMRON CJ1M-CPU11-ETN Manual.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices OMRON CJ1M-CPU11-ETN Manual.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON CJ1M-CPU11-ETN Manual.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CJ1M-CPU11-ETN Communications Commands.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1M-CPU11-ETN REFERENCE MANUAL.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.