OMRON OMRON E5EN-HSS2HH01BD-FLK Manual E5EN-HSS2HH01BD-FLK INSTRUCTION Manual E5EN-HSS2HH01BD-FLK
Product model: E5EN-HSS2HH01BD-FLK
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Size: Shielded, M8.
Sensing distance: 1.5 mm.
Model: Output configuration: NPN NO.
Highly Durable Proximity Sensor for.
Tough Environments.
Completely stainless-steel housing.
Aluminum chip immunity.
Embedding installation to metal (steel) fittings.
Chemical resistance certified by Ecolab Europe E5EN-HSS2HH01BD-FLK INSTRUCTION Manual.
Lineup includes pre-wire models and DC 3-wire NPN output,
models with fluororesin coating E5EN-HSS2HH01BD-FLK Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3.2 dia.
Protective tubing length L: 35cm.
Lead wire type: Heat resistive.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-HSS2HH01BD-FLK INSTRUCTION Manual.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Setting: simulation settings.
Indication mode: no indication.
Adjustment mode: ON/OFF action.
Output: relay E5EN-HSS2HH01BD-FLK INSTRUCTION Manual.
Input: thermocouple K.
The size of the DIN48 to achieve the simulation set, low cost.
The most small and realize the low cost of.
Proportional (P) action in the regulation mode.
And the reset function is added.
Through the installation of the adapter can be continuously close.
The installation of DIN guide rail and panel mounting can be carried out by means of insertion. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes thhe process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5EN-HSS2HH01BD-FLK Manual.
Through the infrared port can be carried out from the frront of the communication E5EN-HSS2HH01BD-FLK Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.