LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> EE-SX772A-ECON
OMRON EE-SX772A-ECON Manual EE-SX772A-ECON INSTRUCTION sheet
Product model: EE-SX772A-ECON
Name: photomicrosensor
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Fitting materials: PBT (polybutylene terephthalate).
Count: 1 .
Accessories: Description, --;
Material, --;
Count, --.
Applicable sensor (mounting pitch on sensor side): E3T-FD@@M.
Page: Dimensions, 16. Size: M12 (brass), single distance, non shield type.
Detection range: 5mm.
Connection mode: lead type (cable length is 2M and 5m two) EE-SX772A-ECON INSTRUCTION sheet.
Thread length: Standard type EE-SX772A-ECON
Output type: NPN.
Action mode NC.
Set up the new standard of the world economy proximity sensor.
OMRON as a pioneer and leader in proximity sensor industry,
Now bring you a new E2B proximity sensor with high performance to price ratio.
This series of products are complete,
Aimed at reasonable prices to meet customer demand for high quality and high reliability of the sensor EE-SX772A-ECON INSTRUCTION sheet.
We have tested the product not only on the protection level (IP67) specific item,
The oil spray test was carried out on the condition of the work site.
Simulation test was carried out in the environment of high oil mist concentration. Detection methods: on the radio type (projector + optical device).
Connection mode: lead type (2 m)
Detection distance: infrared 20m EE-SX772A-ECON INSTRUCTION sheet.
Output mode: PNP output.
Optical projector: 2M E3Z-FTP12-L.
Optical device: 2M E3Z-FTP12-D. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the TTemperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV EE-SX772A-ECON Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs EE-SX772A-ECON Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Photomicrosensor with Slim Cable
EE-SX770 2M
OMRON Photomicrosensor with Slim Cable EE-SX770 2M
Appearance: Standard. Sensing method: T
OMRON
Photomicrosensor with Slim Cable
EE-SX772R 2M
OMRON Photomicrosensor with Slim Cable EE-SX772R 2M
Appearance: T-shaped. Sensing method: T
OMRON
Photomicrosensor with Slim Cable
EE-SX772 2M
OMRON Photomicrosensor with Slim Cable EE-SX772 2M
Appearance: T-shaped. Sensing method: T