Sensing method: Grooved type.
Appearance: --.
Connection method: Pre-wired .
Sensing distance: 10 mm.
Model: NPN Voltage output type .
Both Red-light Models and Green,
light Models to Detect a Wide Variety,
of Colors. Sensing method: Retro reflective wit MSR functio.
Connection method: Connector (M8, 4 pins) E5ER-QT3DB-FLK INSTRUCTION Manual.
Sensing distance: 4 m (100 mm )(Using E39-R1S)
E5ER-QT3DB-FLK
Model: NPN output .
Stainless Steel Housing Ideal for Food Industry PAT Pending.
Strong resistance against detergents, disinfectants, and jet liquid flow.
Product lineup includes BGS Reflective Models and Through-beam,
Models with built-in slits.
Certified by Ecolab Europe. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia E5ER-QT3DB-FLK INSTRUCTION Manual.
Protective tubing length L: 35 cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5ER-QT3DB-FLK INSTRUCTION Manual. E32-T25YR type: standard type; soft (new standard),
Specialty: plane shape (small) side,
Shape / detection distance (mm): 60; 50; 25 (10),
Standard test object
(minimum test object) (mm) 1: 0.5 (0.005),
Fiber element for meeting diversified needsAppearance: Shielded, 8 dia.
Sensing distance: 2 mm.
Output configuration: DC 3-wire PNP.
Model: Operation mode: NO.
Improved Durability with.
Stainless Steel Sensing.
Head.
Models with improved spatter resistance ideal,
for welding also available. E3JK-D91J diffuse reflection type,
E3JK communication type: mode; shading ON,
Miniature amplifier built-in type photoelectric switchSize: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makkes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5ER-QT3DB-FLK Manual.
Through the infrared port can be carried out from the frront of the communication E5ER-QT3DB-FLK Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.