LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> E5EC-TPR4ASM-064
OMRON E5EC-TPR4ASM-064 Manual E5EC-TPR4ASM-064 INSTRUCTION Manual
Product model: E5EC-TPR4ASM-064
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Sensor type: BGS (background suppression).
Sensing distance: 100 mm.
Connection method: pre-wired.
Model: PNP output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications E5EC-TPR4ASM-064 INSTRUCTION Manual.
Non-stop detection E5EC-TPR4ASM-064
High quality and reliability.
High EMC protection.
High light immunity.
Robust and waterproof housing. E32-D11R type: standard type; soft (new standard),
Specialty: M6 screw,
Bending radius (mm): R; R1.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsSize: 48 * 48mm, terminal type E5EC-TPR4ASM-064 INSTRUCTION Manual.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E5EC-TPR4ASM-064 INSTRUCTION Manual.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 15cm.
Lead wire type: Heat resistive .
Lead wire length M : 8m.
A Wide Variety of High-precision.
Temperature SSensors E5EC-TPR4ASM-064 Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5EC-TPR4ASM-064 Manual.