LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> E5CN-HR2H01-W-FLK
OMRON E5CN-HR2H01-W-FLK INSTRUCTION Manual temperature controller Manual
Product model: E5CN-HR2H01-W-FLK
Name: temperature controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply E5CN-HR2H01-W-FLK Manual.
Event entry point: 2 E5CN-HR2H01-W-FLK
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E5CN-HR2H01-W-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E5CN-HR2H01-W-FLK Manual. , can be a key operation. Appearance: M12.
Sensing distance: 2 mm.
Connection method: M12 Connector Models.
Cable specifications: --.
Operation mode : NC .
Pin arrangement: 1: +V, 3: 0 V,2: Control output.
Applicable connector code: D OMRON temperature controller Manual.
Model: PNP output.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E OMRON temperature controller Manual.
Standard Sensors for detecting ferrous metals.
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil OMRON temperature controller Manual.
Useful to help prevent disconnection.
Cable protector provided as a standard feature. Sensing method: Diffuse-reflective Sensors.
Appearance: Horizontal.
Connection method: Pre-wired.
Sensing distance: 100 mm (wide view).
Functions: --.
Model: NPN output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5CN-HR2H01-W-FLK INSTRUCTION Manual.
Through the infrared port can be carried out from the frront of the communication E5CN-HR2H01-W-FLK Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products