Sensing method: Through-beam type.
Output type: NPN output.
Output configuration: Dark-ON or Light-ON (selectable).
Cable length: 1 m.
Liquid Level Photomicrosensor with,
operation mode and sensitivity selectors,
for easy application.
Operation mode selector allows modes to be switched easily E5C4 INSTRUCTION Manual.
Sensitivity selector is suitable for any 6- to 13-mm-diameter transparent or,
semi-transparent pipe with a wall thickness of 1 mm
E5C4
Uses a clean (with no powder parting agent) cable.
Operating voltage range: 12 to 24 VDC. Lead wire length: 1 m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5C4 INSTRUCTION Manual.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard E5C4 INSTRUCTION Manual.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(autommatic / manual, RUN/STOP, alarm), interactive display PV/SV E5C4 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5C4 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.