OMRON E5AN-HAA2HBMD-W-500 Manual E5AN-HAA2HBMD-W-500 INSTRUCTION Manual
Product model: E5AN-HAA2HBMD-W-500
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Appearance: Shielded, 3.8 dia.
Stable sensing area: 0.8 (1.8) mm.
Separate Amplifier Sensor with.
Sensitivity Adjustment.
Compact design with smaller Sensor Head.
Heat-resistance model available for application between.
-10 and 200°C. E3F3-R67M detection methods: Regression reflection type,
Lead extraction: CN M12,
Type: metal appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyFree change detection direction E5AN-HAA2HBMD-W-500 INSTRUCTION Manual E5AN-HAA2HBMD-W-500
Detection direction can be according to the front, side (up and down, around 90 units) change.
Can be similar to the feeling of a limit switch installation E5AN-HAA2HBMD-W-500 INSTRUCTION Manual.
Type: AC type.
Shape: non shield.
Detection range: 30mm.
Action mode: NO/NC (toggle). CompoNet sensor communication unit, simplify sensor settings and management.
No program can be transmitted to the ON/OFF signal PLC (CompoNet communication from the station function).
Support setting content to the detection threshold, quantity and function of reading, writing and teaching operation (explicit message function) E5AN-HAA2HBMD-W-500 INSTRUCTION Manual.
The assembly is simple, just use the communication cable to connect the E3X-CRT and the amplifier next to it.
Up to 16 sensor amplifiers can be connected. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5AN-HAA2HBMD-W-500 Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault