Sensing method: Distance-settable(BGS Models).
Connection method: Pre-wired (2 m).
Response time: 0.5 ms.
Sensing distance: 125 to 40 mm (Min. distance set),
25 to 300 mm (Max. distance set) .
Model: PNP output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC) E4B-T1F4 .
Product lineup includes models with distance setting without,
influence of color
E4B-T1F4
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class.
Type: Shielded.
Appearance: Screw, M10 × 22 mm.
Sensing distance: 2 mm.
Repeat accuracy: 2 μm.
Cable specification: Free cutting.
Proximity Sensor with Separate.
Amplifier Enables Easily Making High E4B-T1F4 .
precision Sensitivity Settings.
Wide variety of Sensor Heads to select according to the,
application. Flexible cables are used between Preamplifiers,
and Amplifier Units of the Sensor Heads.
High resistance to changes in ambient temperature.
Temperature characteristics of 0.08%/°C (for 5.4-dia. models).
Make simple and reliable detection settings with micron,
level precision using the teaching function E4B-T1F4 .
Check the sensing excess gain level on the digital display.
Support for high-precision positioning and screening with,
fine positioning to maximize variations.
The E2C-EDA0 supports an EtherCAT Sensor,
Communications Unit or CompoNet Sensor,
Communications Unit. Fitting materials: Stainless steel(SUS304).
Count: 1 .
Accessories: Description, Phillips screw Nut plat;
Material, Stainless steel Stainless steel;
Count, 2, 1.
Applicable sensor (mounting pitch on sensor side): E3NC-LH03.
Page: Dimensions, 16. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperrature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E4B-T1F4 INSTRUCTION sheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E4B-T1F4 INSTRUCTION sheet.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.