LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> E3ZM-V61
OMRON E3ZM-V61 INSTRUCTION sheet photoelectric sensors Manual
Product model: E3ZM-V61
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Item: Advanced models, ATC function.
Functions: ATC (Active Threshold Control).
Model: PNP output.
Variable Laser Beam for Spot, Line, or Area Detection.
Long-distance detection (diffuse reflective: 1 m, retro-reflective: 7 m).
Beam shape selectable from spot, line, and area types to match various applications E3ZM-V61 Manual.
Adjustable spot diameter.
Adjustable optical axis.
The E3DC-LDA0, which supports the EtherCAT Sensor E3ZM-V61
Communications Unit and the CompoNet Sensor.
Communications Unit, is also included in product lineup. Power supply voltage: DC.
Sensing method: Through-beam (Emitter + Receiver).
Sensing distance: 5 m.
Output configu ration: NPN.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies E3ZM-V61 Manual.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models).
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflective: 2.5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance.
Improved operability E3ZM-V61 Manual.
(Enlarged sensitivity adjuster and operation selector)
Freely selectable power supply input (24 to 240 VDC, 24 to 240 VAC).
(Additional types added to the DC type lineup.)
Models with infrared LEDs are also available. High performance price ratio standard type proximity sensor OMRON photoelectric sensors Manual.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / wire type.
Shape: non shield, M18 OMRON photoelectric sensors Manual.
Detection range: 10mm.
Output configuration: NPN.
Action mode: NC. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points OMRON photoelectric sensors Manual.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to checck the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E3ZM-V61 INSTRUCTION sheet.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E3ZM-V61 Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
Related products
OMRON
Compact Photoelectric Sensor
E3ZM-LS64H
OMRON Compact Photoelectric Sensor  E3ZM-LS64H
Sensing method: BGS reflective fixed di
OMRON
Compact Photoelectric Sensor
E3ZM-T88
OMRON Compact Photoelectric Sensor  E3ZM-T88
Sensing method: Through eam Emitter
OMRON
Compact Photoelectric Sensor
E3ZM-D87
OMRON Compact Photoelectric Sensor  E3ZM-D87
Sensing method: Diffuse reflective. Con
OMRON
Compact Photoelectric Sensor
E3ZM-T68
OMRON Compact Photoelectric Sensor  E3ZM-T68
Sensing method: Through eam Emitter