OMRON E3T-FT12-M3J INSTRUCTION sheet E3T-FT12-M3J Manual
Product model: E3T-FT12-M3J
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Accurately detects objects placed in,
front of shiny Background.
A shiny background can be used as long as the distance between,
the sensor and the background is 20 mm or more.
Detects minute objects such as a 0.05-mm-dia. pure copper wire.
Small dispersion in sensing distance.
Light modulation effectively reduces external light interference E3T-FT12-M3J INSTRUCTION sheet.
Wide operating voltage range: 5 to 24 VDC E3T-FT12-M3J Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2.
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) *2.
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, None E3T-FT12-M3J INSTRUCTION sheet.
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices E3T-FT12-M3J INSTRUCTION sheet.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit. Type: Device Net.
The DeviceNet Communication Unit That.
Simplifies Managing Sensor Settings.
ON/OFF signals and incident light leveels can be sent to the host,
PLC without any need for programming (DeviceNet communications,
slave functionality) E3T-FT12-M3J Manual.
Threshold values and function settings can be read, written,
or taught (using the Message Communications functtion) E3T-FT12-M3J Manual.
Simply connect the communication cables and slide the Amplifiers,
from the side for wire-saving.
Up to 16 Sensor Amplifiers can be connected.
Related products
OMRON
Photoelectric Sensors
E3T-FT24
OMRON Photoelectric Sensors E3T-FT24
Sensing method: Through-eam Emitter
OMRON
Photoelectric Sensors
E3T-FT13
OMRON Photoelectric Sensors E3T-FT13
Sensing method: Through-eam Emitter
OMRON
Photoelectric Sensors
E3T-FT14
OMRON Photoelectric Sensors E3T-FT14
Sensing method: Through-eam Emitter
OMRON
Photoelectric Sensors
E3T-FT11
OMRON Photoelectric Sensors E3T-FT11
Sensing method: Through-eam Emitter