Control output 1: Relay output.
Control output 2: --.
Auxiliary output: Three.
Communications: --.
Heater burnout: One.
Event inputs: Four.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance E3S-AT41 .
Handles More Applications.
The white PV display with a height of 15
E3S-AT412 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other.
Size: 96 x 96mm.
Type: power AC/DC24V with E3S-AT41 .
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input E3S-AT41 .
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Appearance: M18.
Sensing distance: 10 mm.
Connection method: M12 Connector Models.
Cable specifications: --.
Operation mode : NO .
Pin arrangement: 1: +V, 3: 0 V, 4: Control output.
Applicable connector code: B.
Model: NPN output.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals.
Wide array of variations E3S-AT41 INSTRUCTION sheet. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC annd sensing surface made of material that resists,
cutting oil E3S-AT41 INSTRUCTION sheet.
Useful to help prevent disconnection.
Cable protector provided as a standard feature.