Sensing method: Distance-settable(BGS Models).
Connection method: Connector(M8, 4 pins).
Response time: 0.5 ms.
Sensing distance: 125 to 40 mm (Min. distance set),
25 to 300 mm (Max. distance set) .
Model: PNP output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC) E3S-AT11-M1J-1 INSTRUCTION sheet.
Product lineup includes models with distance setting without,
influence of color
E3S-AT11-M1J-1
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class.
Control output: Voltage output.
Auxiliary output: Two.
Communications: --.
Heater burnot: --.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs E3S-AT11-M1J-1 INSTRUCTION sheet.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance.
High-speed sampling at 50 ms for applications with high-speed,
temperature increases E3S-AT11-M1J-1 INSTRUCTION sheet.
Easy connections to a PLC with programless communications.
Models are available with up to 2 auxiliary outputs and 1 event input to,
complete basic functions.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel. Item: Advanced models with simultaneous 2-color determination.
Functions: Standard models + Simultaneous 2-color determination AND/OR output, Remote setting.
Model: NPN output.
Easy and Reliable.
The Fiber Amplifier Unit That Sees in Color.
High-power white LED and multi-RGB processing eliminate the need,
to select light source (wavelength) types.
One-touch teaching enables stable detection that resists against,
workpiece vibration.
Choose from a wide range of Fiber Heads to match the workpiece and,
working space. Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E3S-AT11-M1J-1 Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault