Appearance: 4 dia.
Sensing distance: 1.2 mm.
Connecting method: M8 Pre-wired Connector Models (0.3 m).
Cable specifications: PVC (oil-resistant).
Operation mode: NC.
Wire color /pin arrangement: 1: +V, 3: 0 V, 4: Control output.
Model: NPN output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5 E2FM-X2D1 . 4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available
E2FM-X2D1
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only) E2FM-X2D1 .
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables.
The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points E2FM-X2D1 .
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: position ratio control.
Auxiliary output points: 2 points.
Event entry point: 2.
Remote SP:4 to 20mA input.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E2FM-X2D1 INSTRUCTION sheet.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E2FM-X2D1 INSTRUCTION sheet.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.