Appearance: M30.
Sensing distance: 18 mm.
Connection method: Pre-wired Models (2 m).
Cable specifications: PVC (oil-resistant).
Operation mode : NC .
Pin arrangement: --.
Applicable connector code: --.
Model: NPN output.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E E2EH-X3D2-M1G Manual.
Standard Sensors for detecting ferrous metals
E2EH-X3D2-M1G
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection E2EH-X3D2-M1G Manual.
Cable protector provided as a standard feature. Appearance: Shielded, M18.
Sensing distance: 8 mm.
Output configuration: DC 2-wire (no polarity).
Operation mode: NO.
Spatter-resistant Fluororesin,
coated Proximity Sensor.
Superior spatter resistance.
Long Sensing-distance Models added for sensing,
distances up to 15 mm.
Pre-wired Smartclick Connector Models are also available E2EH-X3D2-M1G Manual. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function OMRON proximity switch Manual.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input OMRON proximity switch Manual.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0 OMRON proximity switch Manual. 01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) maakes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E2EH-X3D2-M1G INSTRUCTION sheet.
Through the infrared port can be carried out from the frront of the communication E2EH-X3D2-M1G Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.