OMRON DRT2-OD08C Manual DRT2-OD08C INSTRUCTION Manual
Product model: DRT2-OD08C
Name: remote i/o terminal
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Release key type: Special release key.
Indicator: Orange.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns DRT2-OD08C INSTRUCTION Manual.
Standard gold-clad contacts enable use with ordinary loads,
and microloads DRT2-OD08C
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Short/disconnection detection: Supported DRT2-OD08C INSTRUCTION Manual.
Specifications: I/O, PNP (input: - common, output: + common), 16 inputs/16 outputs.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance DRT2-OD08C INSTRUCTION Manual.
Single-step wiring by simply inserting pole terminals. Type of drive rod: plunger type.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (2NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Type: Welding / wire type, with left column.
Driving rod: long swing rod type.
Terminal specifications: with wire, the right side of the lead.
Contact specificaations: 1b DRT2-OD08C Manual.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used ffor easy long stroke specifications (OT reference value: 1 DRT2-OD08C Manual. 4mm).
Without harmful substances to the environment, the lead type has also been lead-free.