OMRON D4NS-5BF INSTRUCTION sheet safety-door switch Manual
Product model: D4NS-5BF
Name: safety-door switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Sealed crossroller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4NS-5BF Manual. )
Sealing characteristics that meet IEC IP67 degree of protection D4NS-5BF
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables D4NS-5BF Manual.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Type: M5.
Actuator: Cone-shaped actuator.
Cable length: 5 m.
Detects Objects in Multiple Directions,
with High Sensitivity, Ideal for Robotics,
Slow-action switching mechanism used D4NS-5BF Manual.
Gold-plated contact with coil spring capable of switching,
micro current/voltage load while providing high contact reliability.
Inputs directly to microcomputers and programmable controllers.
Three sizes (M10, M8, and M5) and three types of compact actuators OMRON safety-door switch Manual.
Easy panel mounting. Type: Welding / wire type, with right column.
Driving rod: swing lever type OMRON safety-door switch Manual.
Terminal specifications: with wire, the right side of the lead.
Contact specifications: 1b.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment OMRON safety-door switch Manual.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Type: Welding / wire type, with left column.
Driving rod: R type swing lever type.
Terminal specifications: with wire, the left side.
Contact specifiications: 1b D4NS-5BF INSTRUCTION sheet.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used ffor easy long stroke specifications (OT reference value: 1 D4NS-5BF Manual. 4mm).
Without harmful substances to the environment, the lead type has also been lead-free.
Related products
OMRON
Safety-door Switch
D4NS-4EF
OMRON Safety-door Switch D4NS-4EF
Type: 1-Conduit. Contact configuration:
OMRON
Safety-door Switch
D4NS-2CF-SJ
OMRON Safety-door Switch D4NS-2CF-SJ
Type: 1-Conduit High pull-force type.
OMRON
Safety-door Switch
D4NS-1BF
OMRON Safety-door Switch D4NS-1BF
Type: 1-Conduit. Contact configuration:
OMRON
Safety-door Switch
D4NS-9EF
OMRON Safety-door Switch D4NS-9EF
Type: 1-Conduit, with connector. Contac