Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Pin plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection D4NL-4EFG-B4-NPT Manual.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
D4NL-4EFG-B4-NPT
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4NL-4EFG-B4-NPT Manual.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: Arm lever.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO MBB (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving D4NL-4EFG-B4-NPT Manual.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability OMRON guard lock safety-door switch Manual.
Can be used with both standard loads and microloads. Release Key Type: Special (resin) OMRON guard lock safety-door switch Manual.
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @ OMRON guard lock safety-door switch Manual.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point D4NL-4EFG-B4-NPT INSTRUCTION sheet.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4NL-4EFG-B4-NPT Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.