Receptacle box: G 1/2 Conduit.
Indicator: With LED indicator (DC).
Actuator: Roller lever *1, Maintained *2.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) D4N-3187 INSTRUCTION sheet.
Wide standard operating temperature range:
-40°C to +100°C (standard type)
D4N-3187
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model D4N-3187 INSTRUCTION sheet. ) Multi-contact, Labor-saving,
Environment-friendly, Next,
generation Safety-door Switch.
Lineup includes three contact models with 2NC/1NO,
and 3NC contact forms and MBB models in addition,
to the previous contact forms 1NC/1NO, and 2NC.
M12-connector models are available, saving on,
labor and simplifying replacement.
Standardized gold-clad contacts provide high,
contact reliability D4N-3187 INSTRUCTION sheet.
Applicable to both standard loads and microloads.
Variety of metallic heads available. Receptacle box: G 1/2 Conduit.
Indicator: With LED indicator (DC).
Actuator: Side plunger, Vertical roller.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.) Type: 1-conduit.
Mounting direction: Front-side mounting.
Conduit size: G1/2.
2NC (Slow-action).
The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts.
and Shut Off Control Circuits when Protective.
Doors Are Opened on Machine Tools or Other.
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL and CSA standdards D4N-3187 Manual.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened. The EN-certified.
direct opening mechanism is indicated by on the Switch.
Malfunctions and false operationn prevented by special Operation Key D4N-3187 Manual.
Wide temperature range specifications: −40 to 80°C.
Degree of protection of the switch box: IP67 (EN60947-5-1).