Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms D4B-1315N INSTRUCTION sheet.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
D4B-1315N
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Release key type: Special release key D4B-1315N INSTRUCTION sheet.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+2NC/1NO.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads D4B-1315N INSTRUCTION sheet.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Ratings: 3 A.
Actuator: Hinge lever.
Terminals: PCB terminals.
Contact form: SPDT.
Sealed Subminiature Basic.
Switch Conforming to IP67.
(Excluding the terminals on terminal models).
Use of epoxy resin assures stable sealing,
making this switch ideal for places subject to,
water spray or excessive dust.
Ideal for automobiles, automatic vending,
machines, refrigerators, ice-making equipment,
bath equipment, hot-water supply systems, air,
conditioners, and industrial equipments, which,
require high environmental resistance.
Models available with UL, CSA, and VDE safety,
standard compliance. Actuator: Pin plunger.
Type: M5.
Operation Indicator: None.
Repeat accuracy: 3 µm max.
Operating force OF max: 0.29 N.
Cable lead outlet: Lead outlet, Pre-wired; Length, 1 m.
Degree of protection: IP40.
High-precision Switch for Detecting Micron-unit,
Displacemennt D4B-1315N Manual.
Ideal for detecting and measuring wear of cutting,
tools or for original point of work.
Ceramic plungers on M5, M8, and slim models for,
superior abrasion resistance and resistance to,
temperature changes.
Direct input posssible to microprocessors and,
programmable controllers D4B-1315N Manual.
A version with screw-type cable connector available,