C500-AD Special I/O Unit Analog Input C500-AD501.
Input: 16 pts.
Specification: 0~+5V, 0~+10V, -5~+5V
-10~+10V, 0~+20mA, -20~+20mA.Unit type: CS1 Basic I/O Units.
Product name: B7A Interface Unit.
Specifications: 32 inputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No CP1W-8ET I/O Wiring Diagram.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No
CP1W-8ET
Words required: 2 words.
Current consumption: 5V system, 0.09A;
26 V system, --.
Standards: UC1, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control.Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit CP1W-8ET I/O Wiring Diagram.
I/O points: 8 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 .
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1 CP1W-8ET I/O Wiring Diagram.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CP1W-8ET Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1W-8ET Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.