Product name: NA-type CPU Units with 20 I/O Points (Built-inanalog).
Specifications: Power Supply, 100 to 240 VAC; Inputs,
12(Built-inanalog inputs: 2; Outputs, 8(Built-inanalog outputs: 1;
Output type: Relay.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0 CJ2H-CPU68-EIP INSTRUCTIONS REFERENCE MANUAL. 30A.
Current consumption: 5 V, 0.18A; 24 V,0.11A
CJ2H-CPU68-EIP
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CJ2H-CPU68-EIP INSTRUCTIONS REFERENCE MANUAL. Specifications: 16 Kwords with clock.Model: CPM2A-40CDT1-D. Power supply: DC power supply.
Output type: Transistor sourcing.
Inputs points: 24 points.
Outputs points: 16 points.Name: Compact Connectors.
Specifications: Inputs; 2 outputs; PNP.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery.
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit CJ2H-CPU68-EIP INSTRUCTIONS REFERENCE MANUAL.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices.
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price.
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications. C200HW Backplane PLATE ALPHA CPU ADAPTOR C200HW-AB001Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ±5 V, 0 to 10 V, ±10 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CJ2H-CPU68-EIP Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ2H-CPU68-EIP Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.