Model : CV500-CN432.
Cable I / O connection.
40M cable length.Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ±5 V, 0 to 10 V, ±10 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block CJ2H-CPU65-EIP Safety Precautions.
No. of unit numbers allocated: 1
CJ2H-CPU65-EIP
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value CJ2H-CPU65-EIP Safety Precautions.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CJ2H-CPU65-EIP Safety Precautions.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Product name: N@@S1- type CPU Units with 30 I/O Points.
Specifications: Power Supply, DC24V; Inputs, 18; Outputs, 12;
Output type: Transistor (sourcing).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.27A; 24 V,0.02A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Unit type: CS1 Special I/O Units.
Product name: Power Transducer Input Unit.
Input points : 8 inputs.
Signal range: 0 to 1 mA, ±1 mA.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CJ2H-CPU65-EIP Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ2H-CPU65-EIP Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.