LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> CJ1W-PD025
OMRON CJ1W-PD025 Manual CJ1W-PD025 Safety Precautions
Product model: CJ1W-PD025
Name: Power Supply Unit
Brand: OMRON
Sort: Safety Precautions
File language: English
Name: Temperature Control Module.
Model: C200H-TC103.
Sensor: Platinum resistance thermometer: JPt100 Pt100.
Control output: Current output.Name: Analog I/O Slave Units.
Specifications: Analog outputs;
2 outputs.
Standards: CE, U, U1, C, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CJ1W-PD025 Safety Precautions.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CJ1W-PD025
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CJ1W-PD025 Safety Precautions. Model: CPM2C-10EDR. Units with 10 I/O points.
1 I/O terminal block.
Inputs: 6 inputs.
Outputs: 4 outputs.
Input type: 24 VDC.
Output type: relay.Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ±5 V, 0 to 10 V, ±10 V.
Conversion speed (resolution):
100ms/4 inputs CJ1W-PD025 Safety Precautions.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and sppace compared,
with previous systems CJ1W-PD025 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1W-PD025 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
Related products
OMRON
Position Control Units
CJ1W-NC433
OMRON Position Control Units CJ1W-NC433
Unit classification: CJ1 Special I/O Uni
OMRON
Mixed I/O Units
CJ1W-MD261
OMRON Mixed I/O Units CJ1W-MD261
Unit type: CJ1 Basic I/O Units. Produ
OMRON
CJ-series Input Units
CJ1W-ID232
OMRON CJ-series Input Units CJ1W-ID232
Unit type: CJ1 Basic I/O Units. Produc
OMRON
Programmable Controllers
CS1D-PD025
OMRON Programmable Controllers CS1D-PD025
Name: DC Power Supply Unit. Power suppl