Programmed using the Fuzzy Support Software. Up to 8 inputs and 4 outputs.Output method: Transistor sinking.
Inputs: ---.
Outputs: 16.C500-DA Special I/O Unit Analog Output C500-DA101.
Output: 4 pts.
Specification: +1~+5V、0~+10V、4~20mA.Specification: Thermocouple input (K, J, L, T, R, S, B),
heater burnout alarm,
ON/OFF or advanced PID control,
manual operation,
transistor (NPN) output, 2 loops CJ1H-CPU66H
CJ1H-CPU66H Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CJ1H-CPU66H .
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: CS-series Special I/O Units CJ1H-CPU66H .
Product name: Analog Input Units.
Specifications: I/O points, 4 inputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/8,000 (Settable to 1/4,000);
Conversion speed, 250 s/point max.
(Settable to 1 ms/point).
Externa connection, Removable terminal block.
Current consumption: 5V, 0.12A; 26V, 0.09A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals. Model: C200H-OD211.
No. of points: 12 pts.
Specifications: 0.3 A, 24 VDC.C500-OC I/O Unit Transistor Output 32 pts C500-OC224-E(3G2A5-OC224-E).
AC250/DC24V 2A.Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Specifications: I/O points, 32 inputs(High speed);
Input voltage and current: 24 VDC, 4.1 mA;
Commons, 16 points, 1 common; External connection,
MIL connector; No. of words allocated, 2 word.
Current consumption: 5V, 0.20A; 244V, -- CJ1H-CPU66H INSTRUCTIONS REFERENCE MANUAL.
Standards: N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memoory in the CPU Unit CJ1H-CPU66H INSTRUCTIONS REFERENCE MANUAL.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput.