LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q80BD-J71LP21GE
MITSUBISHI Q80BD-J71LP21GE Hardware User's Manual
Product model: Q80BD-J71LP21GE
Name: MELSECNET/H Interface Board
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
Adapter for mounting DIN guide rail.
For Q32SB, Q33SB, Q35SB, Q33B, Q52B, Q55B, Q63B.PCI bus.
Support Japanese, English OS.
Master / local station sharing.
Support Ver.2 CC-Link version.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q80BD-J71LP21GE Hardware Q80BD-J71LP21GE
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module Q80BD-J71LP21GE Hardware.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time Q80BD-J71LP21GE Hardware.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stationss, the length of the total cable length, strong anti-interference Q80BD-J71LP21GE User's Manual.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system Q80BD-J71LP21GE User's Manual. ..... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.