2 channel.
Input: DC4~20mA (connecting two wire transmitter); DC0~20mA.
Output (resolution): 0~4000. 0~12000.
Conversion speed: 10ms/ channel.
40 pin connector.
Isolation between channels.
Power supply to a two wire transmitter.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark Q64DA User's Manual
Q64DA
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier Q64DA User's Manual.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module."Input: 2 channels.
200/100/10kpps Q64DA User's Manual.
Counter input signal: DC5/12/24V.
External input: DC5/12/24V.
Uniform output: Transistor (drain type).
DC12/24V.
0.1A/ point.
0.4A/ common end.
40 pin connector.
Support high resolution devices. Pulse input and high speed counter module product group satisfying high speed and high precision control application.
High speed counter module for counting high-speed pulse train.
Can be used in combination with the external encoder for positioning and other control.
The maximum count rate can be switched, and the low frequency pulse is counted from the high speed pulse to the rising edge / falling edge.
Each 1 channel is equipped with 2 points of external uniform output.
Can be selected according to the use of "consistent output function", "continuous comparison function", to achieve high-speed control of external equipment. (QD64D2)
Provides a variety of functions, such as the same output test function (using a continuous comparison function), the default function, the latch counter fuunction,
In order to meet the needs of various applications Q64DA Manual. (QD64D2)
The maximum count rate of the input pulse can be up to 8Mpps (differential input, 2 phase, 4 double frequency).
Can be in the semiconductor, liquid crystal manuufacturing and other high position accuracy requirements of the equipment,
Perform accurate position tracking using high resolution encoders Q64DA Manual. (QD65PD2)"