LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q50UDEHCPU
MITSUBISHI Q50UDEHCPU PID Control Instructions Programming Manual
Product model: Q50UDEHCPU
Name: CPU
Brand: MITSUBISHI
Sort: PID Control Instructions Programming Manual
File language: English
Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic Q50UDEHCPU PID Control Instructions Q50UDEHCPU
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Master station.
Support DB A20 AnyWire system.
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability Q50UDEHCPU PID Control Instructions.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines."1ch RS-232.
1ch RS-422/485.
QJ71C24N (-R2) through the RS-232 serial communication,
Programming and monitoring of programmable controllers using programming tools Q50UDEHCPU PID Control Instructions.
QJ71C24N (-R2) with the function of the modem corresponding to the public telephone line,
Can be used to initialize the modem, and the connection of the object device processing,
Communication with a remote device, a programming tool, a modem, and a public telephone line.
Using remote password,
Can be prevented by QJ71C24N (-R2) function of the modem Q series programmable controller for illegal access.
Serial communication module capable of collecting and changing data of programmable controller, monitoring and managing, measuring data collection and so on.
Can achieve the highest speed of 230.4kbps, the maximum of 960 words (MC protocol communications) of the high speed and large capacity communications.
Can use MC pprotocol, through the external devices (PC, monitors, etc Q50UDEHCPU Programming Manual . ) to implement the data read / write programmable controller.
By selecting a non sequential protocol and use sequential program for communication control, the pprogrammable controller and the external device (barcode reader and measurement equipment),
Communication with local protocols using external devices Q50UDEHCPU Programming Manual . "
Related products
MITSUBISHI
With Ethernet CPU
Q10UDEHCPU
MITSUBISHI With Ethernet CPU Q10UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q13UDEHCPU
MITSUBISHI With Ethernet CPU Q13UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q100UDEHCPU
MITSUBISHI With Ethernet CPU Q100UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q26UDEHCPU
MITSUBISHI With Ethernet CPU Q26UDEHCPU
Input / output points: 4096 points. Num