16 axes.
Connect SSCNET III.
Control unit: pulse.
Location data: 32 data / axis.
Ideal solution for simple multi axis positioning.
A variety of functions, such as positioning control, constant velocity control, and other positioning control systems.
The multi axis system is most suitable for simple positioning control Q173NCCPU-S01 Programming Guide Book.
Ideal selection for high speed linear positioning control in multi axis system Q173NCCPU-S01
Linear interpolation operation with up to 4 axes can be carried out.
With the electronic gear, gap compensation, absolute position system, such as basic positioning function. Measurement items: leakage current (Io), resistive leakage current (Ior).
Measuring circuit number: 2 circuits.
Insulation monitoring module for measuring leakage current Q173NCCPU-S01 Programming Guide Book.
Leakage current can be measured to ensure safety by monitoring the leakage current (Io), can detect the risk of electric shock.
Insulation state measurement of resistive leakage current (Ior) can be monitored continuously and continuously,
In order to continuously monitor the insulation aging status of the equipment.
Each measurement project can be carried out in the 2 phase of the alarm monitoring can be respectively on the leakage current (Io), resistive leakage current (Ior) for the 2 phase of the alarm monitoring,
No ladder diagram program Q173NCCPU-S01 Programming Guide Book. Alarm monitoring is divided into 2 stages of attention alarm and danger alarm.
A module can measure two circuits of a module can be two circuits on the same line in the same system type power measurement.
In addition, Works2 GX (1.90U version or higher version) can be used to easily set the parameters.
Leakage current (Io), resistive leakage current (Ior).Output: 2 channels.
Input (resolution): 0~12000; -12000~12000; 0~12000; -16000~16000.
Output DC0~20mA; DC-12~12V.
Conversion speed: 10ms/1 channel.
18 point terminal station.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have beeen greatly reduced due to the need for an external isolation amplifier Q173NCCPU-S01 Manual .
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module. Q173NCCPU-S01 Manual .
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.