4 channel.
Input: DCO~20mA DC-10~10V.
Output (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; 0~16000; -16000~16000;
Conversion speed of 80 s/1 channel.
18 point terminal station.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications Q173HCPU-T Programming Manual.
Can also meet the needs of high speed, high precision control
Q173HCPU-T
Most suitable analog modules for high speed conversion control.
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs Q173HCPU-T Programming Manual.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields Q173HCPU-T Programming Manual.
Can also be used in combination with the CPU module to achieve appropriate control.PCI bus /PCI-X bus.
Support Japanese, English OS.
Multimode fiber optic cable.
Dual loop controller network (control station / common station).
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q173HCPU-T Manual .
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmmission) communication separately, so as to ensure the timeliness of Q173HCPU-T Manual .
Even if the information reaches saturation, it will not affect the link scan time.