"2 axes, SSCNET connection type.
2 axis linear interpolation.
2 axis interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
40 pin connector.
Easy to achieve high speed, high precision positioning control.
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, path switching control, constant speed control etc Q172HCPU-T Strctured Programming Manual
Q172HCPU-T .
In addition, can use the "Configurator-QP GX" and other software,
Easy to set, monitor and debug.
Saving wiring through SSCNET cable connections while simultaneously,
The length of the total cable distance up to 30m.
In addition, an absolute position system for determining the origin position is supported by the return data set operation of the origin Q172HCPU-T Strctured Programming Manual.
No need for the near point block, such as wiring. "Output points: 16 points.
Output voltage and current: 12~24V 0.1A/; DC point; 1.6A/ common.
OFF leakage current: 0.1mA;
Response time: 1ms; 1 point 16 public end; leaky type.
18 point terminal station
With heat protection.
With short circuit protection Q172HCPU-T Strctured Programming Manual.
With the surge absorber.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Easy connection programming tool via ethernet.
Programming tools (Workss2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q172HCPU-T Manual. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method annd the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection Q172HCPU-T Manual.