LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q172DCPU-S1
MITSUBISHI Q172DCPU-S1 Programming Manual PLC Application Functions Manual
Product model: Q172DCPU-S1
Name: PLC
Brand: MITSUBISHI
Sort: Application Functions Programming Manual
File language: English
Input: 2 channels.
Input: thermocouple / micro voltage / voltage / current.
Conversion speed (input):25ms/2 channel.
Sampling period: 25ms/2 channel.
Output: DC4~20mA.
Conversion speed (output):25ms/2 channel.
18 point terminal station.
With 5 kinds of PID control mode.
Loop control module suitable for fast response object control, such as temperature control, flow control, etc Q172DCPU-S1 Manual Q172DCPU-S1 .
The loop control module has a PID control format and a sampling period of 25ms that is proportional to the speed,
Support high precision, high resolution Thermocouple Input, micro voltage input, voltage input, current input and current output.
The most suitable for high speed lift and temperature control and pressure control, flow control and other requirements of the application of high speed response Q172DCPU-S1 Manual .
Can be connected with JIS, IEC, NBS, ASTM standard thermocouple.
Through the small voltage, voltage, current input sensor, can be measured in a variety of input range of analog.
Provides the program control function, can according to the specific requirements of the time automatically change the target value (SV) and PID constant [proportional band (P), integration time (I), differential time (D)],
And cascade control function, allowing channel 1 as the main station, channel 2 for the control from the station Q172DCPU-S1 Manual . 4 axis, differential drive output type MITSUBISHI PLC Manual .
2 axis /4 axis /3 axis linear interpolation.
2 axis interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis MITSUBISHI PLC Manual .
Maximum pulse output: 1Mpps.
40 pin connector.
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control MITSUBISHI PLC Manual .
(the command pulse of the open collector positioning module is highest 200kpps.)
Can also meet the needs of high speed, high precision control.
Most suitable analog modules for high speed conversion control.
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drivve control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields Q172DCPU-S1 Programming Manual.
Can also be used in combination with the CPU module to achieve appropriate control.
The poossibility of expanding control with intelligent function Q172DCPU-S1 Manual .
Providing a variety of analog modules, is the ideal choice for process control applications.
Related products
MITSUBISHI
CPU component
A2SHCPU-S1
MITSUBISHI CPU component A2SHCPU-S1
I/O control method: refresh mode or dire
MITSUBISHI
CPU unit
Q2ASCPU-S1
MITSUBISHI CPU unit Q2ASCPU-S1
Input and output points: 1024 points. In
MITSUBISHI
Motion CPU module
Q172DCPU
MITSUBISHI Motion CPU module Q172DCPU
Control axis: maximum 8 axes. Peripheral
MITSUBISHI
CPU unit
Q2ACPU-S1
MITSUBISHI CPU unit Q2ACPU-S1
Input and output points: 1024 points. In