MITSUBISHI Q170MSCPU Manual Q170MSCPU Special Instructions Strctured Programming Manual
Product model: Q170MSCPU
Name: CPU
Brand: MITSUBISHI
Sort: Special Instructions Strctured Programming Manual
File language: English
Input and output points: 512 points.
Input / output data points: 8192 points.
Program capacity: 28k.
Basic command processing speed (LD command) S:0.075.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program Q170MSCPU Strctured Programming Manual Q170MSCPU
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment Q170MSCPU Strctured Programming Manual. Cable length 5 meters.
Extended substrate for connection.8 channels.
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A.
Output: 0~10000.
18 point terminal.
Directly connected to the CT sensor, saving wiring and space of the CT input module.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc..
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored Q170MSCPU Strctured Programming Manual.
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost.
Set the CT sensor type (input range) for each channel.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will suddeenly change Q170MSCPU Manual.
By detecting the transient peak current at this time, the fault of the equipment can be diagnosed.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value)) Q170MSCPU Manual.
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored.
Related products
MITSUBISHI
Motion controller
Q170MSCPU
MITSUBISHI Motion controller Q170MSCPU
Control axis: up to 16 axes. Interpolati
MITSUBISHI
CPU unit
A2USCPU
MITSUBISHI CPU unit A2USCPU
Input and output points: 512 points. Inp
MITSUBISHI
Motion controller
Q170MCPU
MITSUBISHI Motion controller Q170MCPU
Axis of control: 16. Compact Q170MCPU in
MITSUBISHI
Motion controller
Q173DSCPU
MITSUBISHI Motion controller Q173DSCPU
Control axis: up to 32 axes. Servo ampli