LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q02CPU
MITSUBISHI Q02CPU Manual Q02CPU Structured Text(ST) Programming Guide Book
Product model: Q02CPU
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text(ST) Programming Guide Book
File language: English
Express PCI bus.
Support Japanese, English OS.
Multimode fiber optic cable.
Dual loop controller network (control station / common station).
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2 Q02CPU Programming Guide Book Q02CPU 5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q02CPU Programming Guide Book.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module Q02CPU Programming Guide Book.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.Control axis: up to 32 axes.
Servo amplifier connection mode: SSCNET III /H (2 system).
Caan be carried out with a high degree of control, free correspondence Q02CPU Manual.
Large scale and medium scale system.
Maximum number of control axis: 32 axis (Q173DSCPU), 16 axis (Q172DSCPU).
Programmable controller CPU and C language controller can be selected according to the purpose Q02CPU Manual.
By using 3 sets of Q173DSCPU, 96 axes can be controlled.
Support security monitoring function, visual system.
Related products
MITSUBISHI
CPU unit
Q2ASCPU
MITSUBISHI CPU unit Q2ASCPU
Input and output points: 512 points. Inp
MITSUBISHI
CPU unit
Q4ACPU
MITSUBISHI CPU unit Q4ACPU
Input and output points: 4096 points. In