MITSUBISHI Q01UCPU Manual Q01UCPU MELSAP-L Programming Manual
Product model: Q01UCPU
Name: CPU
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
Multimode fiber optic cable.
Double circuit.
Controller network (control station / common station).
Decentralized control of large scale controller,
IE CC-Link controller network module connected with various field network.
Effectively using Ethernet cable and connector on the market, can reduce the cost Q01UCPU Programming Manual.
The performance of the cycle data update is improved.
The transmission delay time is shortened, and the synchronous waiting time of the application can be shortened Q01UCPU
On the same network to achieve the 256KB network shared memory (cycle data).
No need to distinguish the network can handle large capacity data.
QJ71GP21S-SX, CC-Link can be used as the control station of IE QJ71GP21-SX controller network, common station Q01UCPU Programming Manual. Input: 4 channels.
Platinum resistance (Pt100; JPt100).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q01UCPU Programming Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced. Input voltage range: AC100-240V.
Output voltage: DC5V.
Output power: 8.5A.
Simplified program debugging.
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action.
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Through the expansion of soft components, more convenient to create the program.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.
Auto backup key data.
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To preventt the loss of the program and the parameters due to forgetting to replace the battery Q01UCPU Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and oother planned downtime,
The data is lost due to battery depletion Q01UCPU Manual.
The next time the power is turned on, the backup data will be automatically restored.
Related products
MITSUBISHI
CPU unit
Q2ASCPU
MITSUBISHI CPU unit Q2ASCPU
Input and output points: 512 points. Inp
MITSUBISHI
Basic type CPU
Q00CPU
MITSUBISHI Basic type CPU Q00CPU
Program capacity: 8K step. Input / outpu
MITSUBISHI
General high speed CPU
Q04UDVCPU
MITSUBISHI General high speed CPU Q04UDVCPU
Input / output points: 4096 points. Inpu
MITSUBISHI
CPU unit
A1FXCPU
MITSUBISHI CPU unit A1FXCPU
Input and output points: 224 points. Inp