MITSUBISHI Q00UJCPU Structured Text Programming Manual
Product model: Q00UJCPU
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text Programming Manual
File language: English
Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q00UJCPU Structured Text Q00UJCPU
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected Q00UJCPU Structured Text.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q00UJCPU Structured Text.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced. PCI bus.
Support Japanese, English OS.
SI/QSI/H-PCF/ broadband H-PCF cable.
Dual loop controller network (control station / common station).
With external power supply function.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between statioons, the length of the total cable length, strong anti-interference Q00UJCPU Programming Manual.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system Q00UJCPU Programming Manual. ..... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.
Related products
MITSUBISHI
CPU unit
A2CJCPU
MITSUBISHI CPU unit A2CJCPU
Input points 512, CPU power supply, Item
MITSUBISHI
General purpose CPU
Q00UCPU
MITSUBISHI General purpose CPU Q00UCPU
nput / output points: 1024 points. Nume
MITSUBISHI
General purpose CPU
Q00UJCPU-S8
MITSUBISHI General purpose CPU Q00UJCPU-S8
8 modules can e installed. Input / outp
MITSUBISHI
General purpose CPU
Q00UJCPU
MITSUBISHI General purpose CPU Q00UJCPU
Input / output points: 256 points. Nume