Input points: 16 points.
Input voltage and current: 6mA DC5V.
Response time: 0/0.1/0.2/0.4/0.6/1ms.
8 point /1 a public side.
Common cathode.
18 point terminal station.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q00JCPU Hardware Design. And there is no need to select the cable, the straight line and the cross line can be used
Q00JCPU
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location Q00JCPU Hardware Design.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control Q00JCPU Hardware Design.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password Maintenance and Inspection.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users Maintenance and Inspection.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.Multimode fiber optic cable.
Double circuit.
Controller network (control station / common station).
Decentralized control of large scale controller,
IE CC-Link controller network module connected with various field network Maintenance and Inspection.
Effectively using Ethernet cable and connector on the market, can reduce the cost.
The performance of the cycle data update is iimproved Q00JCPU User's Manual.
The transmission delay time is shortened, and the synchronous waiting time of the application can be shortened.
On the same network to achieve the 256KB network shared memory (cycle data).
No need to distinguish thee network can handle large capacity data Q00JCPU Hardware Design.
QJ71GP21S-SX, CC-Link can be used as the control station of IE QJ71GP21-SX controller network, common station.