Manual Download >> Q02PHCPU
MITSUBISHI MITSUBISHI Q02PHCPU Programming Guide Book PLC Structured Text(ST) Manual Q02PHCPU
Product model: Q02PHCPU
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text(ST) Programming Guide Book
File language: English
Input / output points: 4096 points.
Number of input and output elements: 8192.
Program capacity: 30 K step.
Processing speed: 0.02 s.
Program memory capacity: 120 KB.
Support USB and network.
Support installed memory card.
Providing high speed communication between multiple CPU.
Shorten the fixed scan interrupt time, high precision device Q02PHCPU Manual.
The minimum interval of the fixed period interrupt program is reduced to 100 s Q02PHCPU
The high speed signal can be accurately obtained, which makes the contribution to the higher precision of the device.
High speed and high precision machine control by multi CPU.
By parallel processing of the linear and multi CPU high-speed communication (cycle 0.88ms) of the parallel control program, the high speed control Q02PHCPU Manual.
Multi CPU high speed communication cycle and motion control synchronization, so it can achieve the maximization of computing efficiency.
In addition, the latest movement control CPU in performance is 2 times the previous model,
To ensure high speed and high accuracy of the machine control.8 channels.
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A Q02PHCPU Manual.
Output: 0~10000.
18 point terminal.
Directly connected to the CT sensor, saving wiring and space of the CT input module.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc MITSUBISHI PLC Manual. .
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored MITSUBISHI PLC Manual.
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost MITSUBISHI PLC Manual.
Set the CT sensor type (input range) for each channel.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will sudddenly change Q02PHCPU Programming Guide Book.
By detecting the transient peak current at this time, the fault of the equipment can be diagnosed.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value)) Q02PHCPU Manual.
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored.
Related products
MITSUBISHI
General purpose CPU
Q06UDHCPU
MITSUBISHI General purpose CPU Q06UDHCPU
Input / output points: 4096 points. Num
MITSUBISHI
Process CPU
Q12PHCPU
MITSUBISHI Process CPU Q12PHCPU
Program capacity: 124 K step. Input / ou
MITSUBISHI
General purpose CPU
Q26UDHCPU
MITSUBISHI General purpose CPU Q26UDHCPU
Input / output points: 4096 points. Num