Slim type non isolated.
Input power: DC24V.
Output: DC5V, 5A.
Power supply module can be directly pasted on the printed circuit board of the power supply,
The device is characterized in that a special integrated circuit (ASIC), a digital signal processor (DSP), a microprocessor, a memory, a field programmable gate array (FPGA), and other digital or analog loads are provided L06CPU-P Programming Manual
L06CPU-P
In general, this type of module is called the load point (POL) power supply system or the use of point power supply system (PUPS).
Because of the advantages of the modular structure,
The module power supply is widely used in switching devices, access devices, mobile communications, microwave communications and optical transmission, routers and other communication fields and automotive electronics, aerospace, etc L06CPU-P Programming Manual. . "Output points: 32 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector L06CPU-P Programming Manual.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol. Thermocouple input.
Number of input channels: 4ch.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling.
According to the object device can choose any one of the following control method.
Standard control (heating or cooling).
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control).
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contraact), and reduce the operation cost L06CPU-P Manual .
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniiform, to ensure that the control object no local burning or thermal expansion L06CPU-P Manual .
No idle running, with energy saving effect, can reduce operating costs.