Thermocouple input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode L02SCPU-CM Manual .
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time
L02SCPU-CM To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost L02SCPU-CM Manual .
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs L02SCPU-CM Manual .
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling MITSUBISHI PLC Manual .
According to the object device can choose any one of the following control method.
Standard control (heating or cooling).
Heating, cooling control (heating and cooling) MITSUBISHI PLC Manual .
Hybrid control (combination of standard control and heating, cooling control). Error output.
Rated open and close voltage, current: DC24V, 0.5A.
Minimum open and close load: DC5V, 1mA.
Response time (OFF, ON): 10ms below.
Response time (ON, OFF): 12ms below.
Life (Mechanical): more than 20 million times MITSUBISHI PLC Manual .
Life (Electrical) rated open and close voltage, current more than 100 thousand times.
Suitable for wire specifications: 0.3 ~ 2 square mm (AWG22 ~ 14) (twisted pair / single line).
External wiring connection mode: spring clip terminal.
DC5V internal consumption current: 0.06A.
Weight: 0.11kg. Number of input channels: 2Ch.
Differential drive input.
Maximum count rate: pulse/s 500K.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control.
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision control.
VVelocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement L02SCPU-CM PROGRAMMING Guide Book.
The high precision measurement of the smallest 25ns unit can be realized L02SCPU-CM Manual .
Delayed output