LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> L02CPU-P
MITSUBISHI L02CPU-P Structured Text Programming Guide
Product model: L02CPU-P
Name: Programmable Controller
Brand: MITSUBISHI
Sort: Structured Text Programming Guide
File language: English
Input points: 16 points.
Rated input voltage: AC100 ~ 120V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on L02CPU-P Structured Text L02CPU-P Structured Text L02CPU-P Input points: 32 points.
Input voltage: DC24V.
Enter the public side of the way: 32 points / public.
Output form: transistor output (drain).
Output points: 32 points.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point L02CPU-P Structured Text.
Protection function: have
Output common way: 32 point / common.
Input / output occupied points: 32 points (I/O distribution: input and output mixed 32 points).
External wiring connection: 40 pin connector two.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection funnction, with 3000V photoelectric isolation L02CPU-P Programming Guide.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convennient and flexible L02CPU-P Programming Guide.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability.
Related products
MITSUBISHI
cpu module
L02SCPU-P
MITSUBISHI cpu module L02SCPU-P
"Universal output function: source type.
MITSUBISHI
cpu module
L06CPU-P
MITSUBISHI cpu module L06CPU-P
"Universal output function: source type.
MITSUBISHI
cpu module
L02CPU-P
MITSUBISHI cpu module L02CPU-P
"Universal output function: source type.
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type.