Output points: 16 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.5A/1 point.
Protection function: have.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal L02CPU-P Common Instructions.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called
L02CPU-P
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol L02CPU-P Common Instructions. DB A20 AnyWire master station.
Transmission distance: the longest 3km.
Data input and output: up to 1024 points.
Connect up to 128 units.
Enter 512 points, 512 points out of the output.
Support environmental protection, high speed, long distance transmission and special distribution system to support the special flat cable, universal VCTF cable, universal single wire cable and other cable L02CPU-P Common Instructions.
Using original transmission mode, there is almost no branch limit,
Supports the automatic track and ring transmission,
Can also create suitable for small and medium sized factory wiring system.
Support remote I/O, analog quantity, temperature and humidity terminal, anti false operation terminal and other equipment.
Up to 128 units from the station module
Can connect up to 128 units from the station module, for up to 1024 points (input 512 points / output 512 points) of the I/O control.
In addition, the parameters can be set through the switch, easy to set the transmission distance of 50m/200m/1km/3km. Number of input channels: 4ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 40 s/2ch.
Resolution: 1/32000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continuous analog ooutput L02CPU-P Programming Manual.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period L02CPU-P Programming Manual.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.