LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> L02CPU
MITSUBISHI L02CPU Manual L02CPU Built-In I/O Function User's Manual
Product model: L02CPU
Name: CPU Module
Brand: MITSUBISHI
Sort: Built-In I/O Function User's Manual
File language: English
"Universal output function: leakage type.
Program capacity: 20K step.
Basic operations processing speed: 40ns.
Communication interface: USB/Ethernet.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points.
End cap.
CPU built-in functions can be easily set through programming tools L02CPU User's Manual.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool L02CPU
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated " L02CPU User's Manual.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators L02CPU User's Manual. "Output points: 64 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: output 64 points).
External wiring connection: 40 pin connector two.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol. Output points: 16 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.5A/1 point.
Protection function: have.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the inputt / output of the switch signal,
Digital I/O modules are often called L02CPU Manual.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch L02CPU Manual.
Communication protocol is a standard Modbus protocol or custom protocol.
Related products
MITSUBISHI
CPU component
A1SJHCPU
MITSUBISHI CPU component A1SJHCPU
I/O control method: refresh mode or dire
MITSUBISHI
CPU unit
A2UCPU
MITSUBISHI CPU unit A2UCPU
Input and output points: 512 points. Inp
MITSUBISHI
High performance CPU
Q25HCPU
MITSUBISHI High performance CPU Q25HCPU
Program capacity: 252 K step. Input / ou
MITSUBISHI
Basic type CPU
Q00CPU
MITSUBISHI Basic type CPU Q00CPU
Program capacity: 8K step. Input / outpu