LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> FX3G-40MR/DS
MITSUBISHI FX3G-40MR/DS Manual FX3G-40MR/DS Hardware Edition USER'S MANUAL
Product model: FX3G-40MR/DS
Name: PLC
Brand: MITSUBISHI
Sort: Hardware Edition USER'S MANUAL
File language: English
Cable flat cable;
Connector with 20 pin installed at both ends of the fuse.
Length 5M. Input / output type: DC input (drain / source).
Input and output points: 16 points.
DC5V internal consumption current: 100mA.
DC24V internal consumption current: 85mA.
In order to extend the input output of the device FX3G-40MR/DS USER'S MANUAL.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256 FX3G-40MR/DS
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. "MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V.
Power: 132kw.
SLD converter rated current: 361A.
Structure and function: IP55 counterpart FX3G-40MR/DS USER'S MANUAL.
Type: CA.
Substrate coating: have.
Built in DC reactor.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption.
How to achieve energy efficiency in the plant without affecting the productivity FX3G-40MR/DS USER'S MANUAL.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation of the inverter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements.
The control of each machine can be done separately by the frequency converter, and the control of the dispersion is also carried out.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "MITSUBISHI inverter FR-D720S series.
Voltage level: single phase 200V.
Frequency converter capacity: 1.5KW.
VVVF frequency control, vector control frequency conversion, direct torque control is a kind of AC - DC - AC frequency conversion.
The common drawback is that the input power factor is low, the harmonic current is big, and the DC circuit needs large energy storage capacity,
Renewable energy and can not be fed back to the power grid, which can not be carried out in the four quadrant operation. To this end, the matrix type of AC - AC variable frequency arises at the historic moment.
Because the matrix type alternating current frequency saves the intermediate DC link, thereby, the electrolytic capacitor with large volume and high price can be omitted FX3G-40MR/DS Manual.
It can achieve a power factor of L, the input current is sinusoidal and can run in four quadrant, the power density of the system is large.
Although the technology is not yet mature, but still attract a large number of scholars in-depth study FX3G-40MR/DS Manual.
In fact, the quality is not the indirect control current, flux, but the torque is directly used as the control to achieve.
Related products
MITSUBISHI
PLC
FX3G-40MR/ES-A
MITSUBISHI PLC FX3G-40MR/ES-A
Input points: 24 points. Output points:
MITSUBISHI
Function expansion board
FX3G-4EX-BD
MITSUBISHI Function expansion board FX3G-4EX-BD
Input points: 4 points. Weight: 0.02kg.
MITSUBISHI
PLC
FX3U-80MR/DS
MITSUBISHI PLC FX3U-80MR/DS
Max input / output points: 80 points. Su
MITSUBISHI
PLC
FX3G-40MT/DS
MITSUBISHI PLC FX3G-40MT/DS
Input and output points: 40 points. Powe