LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> FR-D720S-0.2K
MITSUBISHI FR-D720S-0.2K Manual FR-D720S-0.2K BASIC Instruction manual
Product model: FR-D720S-0.2K
Name: INVERTER
Brand: MITSUBISHI
Sort: BASIC Instruction manual
File language: English
MITSUBISHI inverter series: FR-A800.
Voltage level: three phase 400V.
Power: 500kw.
SLD converter rated current: 1212A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
To maximize the performance of the motor.
Advanced auto tuning function.
The newly developed PM motor auto tuning feature can be used to operate other manufacturers of PM motors (Yong Ci synchronous motors) in the sensorless state FR-D720S-0 FR-D720S-0.2K2K Instruction manual.
Not only can drive MITSUBISHI induction motor and PM motor, but also can drive other manufacturers of induction motor and PM motor.
This means that you can reduce the cost of inventory and supplies.
If the PM motor is produced by a IPM motor or other company using MM-CF, the starting torque is limited to 50%,
Even after tuning is not simple to use and positioning control of zero speed torque) induction motor and permanent magnet motor can be combined freely FR-D720S-0.2K Instruction manual. Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points.
Output type: relay.
Power consumption: 30VA.
Weight (kg):0.65.
Size (WxHxD) mm:130x90x87 FR-D720S-0.2K Instruction manual.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, ussing a eight digit password to protect your program FR-D720S-0.2K Manual .
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time FR-D720S-0.2K Manual .
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Related products
MITSUBISHI
Single phase 200V inverter
FR-D720S-0.75K
MITSUBISHI Single phase 200V inverter FR-D720S-0.75K
MITSUBISHI inverter FR-D720S series. Vol
MITSUBISHI
Single phase 200V inverter
FR-D720S-0.1K
MITSUBISHI Single phase 200V inverter FR-D720S-0.1K
MITSUBISHI inverter FR-D720S series. Vol
MITSUBISHI
Single phase 200V inverter
FR-D720S-0.2K
MITSUBISHI Single phase 200V inverter FR-D720S-0.2K
MITSUBISHI inverter FR-D720S series. Vol
MITSUBISHI
Single phase 200V inverter
FR-D720S-1.5K
MITSUBISHI Single phase 200V inverter FR-D720S-1.5K
MITSUBISHI inverter FR-D720S series. Vol