Manual Download >> FR-A820-2.2K-1
MITSUBISHI FR-A820-2.2K-1 Programming Manual INVERTER PLC FUNCTION Manual
Product model: FR-A820-2.2K-1
Name: INVERTER
Brand: MITSUBISHI
Sort: PLC FUNCTION Programming Manual
File language: English
Max input / output points: 20 points.
Power supply voltage: DC24V.
Input points: 12 points.
Output points: 8 points.
Output type: relay.
Power consumption (W): 20.
Weight (kg):0.4.
Size (WxHxD) mm:75x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time FR-A820-2.2K-1 Manual .
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control FR-A820-2.2K-1
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain FR-A820-2.2K-1 Manual .
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication FR-A820-2.2K-1 Manual . Power: 3.7kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed MITSUBISHI INVERTER Manual . Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table MITSUBISHI INVERTER Manual .
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate MITSUBISHI INVERTER Manual .
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor.
The installation of thermal relay, to avoid overheating and burn the braking resistor. Power: 22kw.
Voltage: 200V.
The surge voltage of the motor can be suppressed when the 400V motor is driven by a frequency converter.
Motor suitable for 5.5 to 37kW. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 90KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes.
For the requirements of relatively high precision, even if the load changess are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection) FR-A820-2.2K-1 Programming Manual.
If the given acceleration time is too short, the output frequency of the inverter is far more than thhe change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall FR-A820-2.2K-1 Manual .