MITSUBISHI FR-A7AP TECHNICAL MANUAL FR-A7AP Manual
Product model: FR-A7AP
Name: INVERTER
Brand: MITSUBISHI
Sort: TECHNICAL MANUAL
File language: English
MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 90kw.
SLD converter rated current: 475A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on FR-A7AP TECHNICAL MANUAL FR-A7AP
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units FR-A7AP TECHNICAL MANUAL.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display. Voltage level: three phase 400V.
Applicable motor capacity: 450kw.
Substrate coating: have.
Built in DC reactor.
The operating frequency of the fixed alternating current is converted to DC power. Power: 18.5kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current FR-A7AP TECHNICAL MANUAL.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Connecting cable for handheld GOT and PLC.
Cable length: 3 meters.
Application: RS-422 connection and RS-232C connection. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 500KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is the frequency of the inverter voltage proportionnal to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the mmotor FR-A7AP Manual FR-A7AP Manual .
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity.
Related products
MITSUBISHI
DC reactor
FR-HEL-H18.5K
MITSUBISHI DC reactor FR-HEL-H18.5K
Power: 18.5kw. Purpose: to suppress the
MITSUBISHI
3 phase 400V converter
FR-L740-18.5K-CHT
MITSUBISHI 3 phase 400V converter FR-L740-18.5K-CHT
MITSUBISHI inverter FR-L740 series. Volt
MITSUBISHI
Common DC bus converter
FR-CV-7.5K
MITSUBISHI Common DC bus converter FR-CV-7.5K
Power: 7.5kw. Voltage: 200V. There are 1