MITSUBISHI FR-A720-30K BASIC INSTRUCTION MANUAL
Product model: FR-A720-30K
Name: INVERTER
Brand: MITSUBISHI
Sort: BASIC INSTRUCTION MANUAL
File language: English
MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 15.0kw.
SLD converter rated current: 31.0A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed FR-A720-30K BASIC.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption FR-A720-30K
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control FR-A720-30K BASIC. Power: 15kw.
Voltage: 200V.
The surge voltage of the motor can be suppressed when the 400V motor is driven by a frequency converter.
Motor suitable for 5.5 to 37kW. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output FR-A720-30K BASIC. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 18.5kw.
SLD converter rated current: 93A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on.
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 560KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is the frequency of the inverter voltage proportional to the changge?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the mmotor FR-A720-30K INSTRUCTION MANUAL FR-A720-30K INSTRUCTION MANUAL.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity.
Related products
MITSUBISHI
3 phase 200V converter
FR-A720-45K
MITSUBISHI 3 phase 200V converter FR-A720-45K
MITSUBISHI inverter FR-A720 series. Volt
MITSUBISHI
3 phase 200V converter
FR-A720-1.5K
MITSUBISHI 3 phase 200V converter FR-A720-1.5K
MITSUBISHI inverter FR-A720 series. Volt
MITSUBISHI
3 phase 200V converter
FR-A720-55K
MITSUBISHI 3 phase 200V converter FR-A720-55K
MITSUBISHI inverter FR-A720 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-355K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-355K-CHT
MITSUBISHI inverter FR-A740 series. Volt