"Power: 15kw.
Voltage: 400V.
Brake resistor, a kind of ripple resistance, is mainly used in the mechanical system of the inverter to control the speed of the motor,
Help the motor to be converted into heat energy due to the regenerative power of the motor.
Braking unit principle: the brake unit is composed of a high power transistor GTR and its driving circuit F-20M INSTRUCTION MANUAL.
Its function is to link the discharge current braking resistor capacitor voltage or not in the range of the time consumed and the DC part "overpressure",
Need to add external braking components, in order to speed up the speed of the consumption of renewable energy
F-20M "MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V F-20M INSTRUCTION MANUAL.
Frequency converter capacity: 3.7KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used F-20M INSTRUCTION MANUAL. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft. Connecting cable for handheld GOT and PLC.
Cable length: 3 meters.
Application: RS-422 connection and RS-232C connection. Max input / output points: 128 points.
Supply voltage: 100 - 240VAC.
Input points: 64 points.
Output points: 64 points.
Output type: Transistor (source).
Power consumption: 100VA.
Weight (kg):1.8.
Size (WxHxD) mm:350x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password proteection, using a eight digit password to protect your program F-20M Manual.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time F-20M Manual.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).