MITSUBISHI AJ35TB1-16DT User's Manual I/O MODULE Manual
Product model: AJ35TB1-16DT
Name: I/O MODULE
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Output points: 32 points.
Voltage: DC5/12V.
Output type: Sink type.
Response time: 1ms.
16 points / a common end.
38 point terminal station.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read AJ35TB1-16DT Manual AJ35TB1-16DT
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three AJ35TB1-16DT Manual .
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive AJ35TB1-16DT Manual .
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC MITSUBISHI I/O MODULE Manual .
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation MITSUBISHI I/O MODULE Manual .
Read only memory. Manufacturers use, content can not be changed, power does not disappear. ME-NET interface unit.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program MITSUBISHI I/O MODULE Manual .
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC initialization procedure. AAfter MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system AJ35TB1-16DT User's Manual.
The main contents of the initialization program arre: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc AJ35TB1-16DT Manual . .
Related products
MITSUBISHI
DC input module
AJ35TB2-8D
MITSUBISHI DC input module AJ35TB2-8D
DC input points: 8 points. Input voltage
MITSUBISHI
Transistor output module
AJ35TB2-16T
MITSUBISHI Transistor output module
 AJ35TB2-16T
Output points: 16 points. Output voltage
MITSUBISHI
DC input module
AJ35TB3-8D
MITSUBISHI DC input module AJ35TB3-8D
DC input points: 8 points. Input voltage
MITSUBISHI
AC100V input module
AJ35TB1-16A
MITSUBISHI AC100V input module AJ35TB1-16A
AC input points: 16 points. Input voltag